Gear Coupling Hub Burst Due to Over Torque |
The root cause for this over-torque failure may be that the coupling was undersized for the given application (perhaps the wrong factor of safety was used when calculating required torque), that the application saw a massive unexpected peak load (and perhaps the coupling failing may have saved more expensive equipment from failing), the coupling bore and/or keyway were oversized relative to the maximum bore and keyway combination specified from the manufacturer for the given product size, or the coupling had excessive misalignment.
Jaw Coupling Hub Burst Due to Over Torque |
It is also important to note that, while undersized/underrated couplings are not good and can cause failures... it is also a mistake to significantly oversize a coupling. There are a number of drawbacks to this approach, including excessive overhung loads, potentially reduced performance, and cost.... and should be avoided.
For further information on sizing a coupling, please consider reading "Coupling Service Factors - Best Practices" and "Coupling Sizing Torque - How to Quick Calculate". For further information on misalignment, please see "Top Reason for a Coupling Failure".
To learn more on coupling failure analysis, go to:
And, if you still have questions or concerns... please feel free to contact a Lovejoy application engineer or specialist.